Encore ENDSS-R4D8 Manuale Utente Pagina 68

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 132
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 67
ENDSS-4C8
60
3.9.4.2 RS-485
The DVR uses the RS-485 standard for PTZ communication. The following settings
must be configured in parallel with the local settings of the camera for the system to
function properly.
Baudrate
Select a baud rate: 1200, 1800, 2400, 4800, 9600, 14400, 19200, 38400, 57600 or
115200.
Databit
Select a data bit communication protocol: 8-bit or 7-bit
Parity
Select a parity configuration: Odd, Even, or No Parity
Stopbit
Select a stop bit configuration: 1 Stopbit or 2 Stopbit
NOTE Pan/Tilt/Zoom and RS-485 Settings may vary for each camera. Be
sure to match local camera settings to those you input on the DVR.
3.9.4.3 Keyboard
Keyboard Model
Select the keyboard model you are using: OFF (if there is no keyboard), CK101,
CK201, KB-KT301
Keyboard ID
Adjusts the identification number based on the local settings of your keyboard. This
value may be any number from 1 to 16.
Keyboard Protocol
Provides options for the keyboard communication protocol: Pelco P, Pelco D, Teleview
Pelco P, Teleview Pelco D, Merit LILIN (3B), Merit LILIN (7B), HiSharp, Nicecam and
Elitar. This setting depends on the keyboard model being used.
Vedere la pagina 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 131 132

Commenti su questo manuale

Nessun commento