Encore ENTC-1000 - V1.04 Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Networking Encore ENTC-1000 - V1.04. Encore ENTC-1000 - V1.04 Service manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - CONTROL SYSTEM

EncoreCONTROL SYSTEMInstallation and Service ManualSoftware Version 1.8.1071810311MARCH 2011

Pagina 2 - CERTIFICATE

10 Encore — Installation and Service ManualPreface Additional DocumentationDocumentation for various Encore system options is also available: • Enco

Pagina 3

100 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting 5. Send a SET request for:gvgTtCfgEntryStatus (1.3.6.1.4.1.4

Pagina 4 - Contacting Grass Valley

Encore — Installation and Service Manual 101SNMP Monitoring Matrix Controller Signal Loss TrapsA CPL Matrix Controller can now be configured to send

Pagina 5 - Contents

102 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting

Pagina 6

Encore — Installation and Service Manual 103 Appendix ASpecificationsPower Requirements and Mechanical SpecificationsPerformance and Environmental

Pagina 7

104 Encore — Installation and Service ManualAppendix A — Specifications SIO Ports 1, 2, 3 & 4Type RS-232 or RS-422/485Connector RJ-45Cable Ca

Pagina 8

Encore — Installation and Service Manual 105 Appendix BEncore System Interface GuideIntroductionThis section provides settings that can be used as a

Pagina 9 - About This Manual

106 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide CAUTION Encore control systems employ consecutive IP addresse

Pagina 10 - Additional Documentation

Encore — Installation and Service Manual 107Default Network IP Settings (Concerto 64VAA Example) Default Network IP Settings (Concerto 64VAA Example

Pagina 11 - Safety Summary

108 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide Encore Control of Concerto 64VAA (Ethernet)Table 25. Encore&

Pagina 12 - Warnings

Encore — Installation and Service Manual 109Encore Control of Jupiter (Ethernet) Encore Control of Jupiter (Ethernet)Encore System SettingsTable 26.

Pagina 13 - Cautions

Encore — Installation and Service Manual 11 Safety SummaryRead and follow the important safety information below, noting especially those instructio

Pagina 14

110 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide Jupiter System SettingsNote Only CM-4000 Jupiter systems runn

Pagina 15 - Regulatory Notices

Encore — Installation and Service Manual 111Serial Interfaces Serial InterfacesDevices that do not support Ethernet communications may be controlled

Pagina 16 - Laser Safety

112 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide Encore System SettingsTable 28. Encore Control Jupiter ESswi

Pagina 17 - Certification

Encore — Installation and Service Manual 113Encore Control of Jupiter (Serial) Jupiter System SettingsCable ConnectionsUse the same connectors, adap

Pagina 18

114 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide Jupiter Serial RS-422/485 Cable Pin AssignmentsThe pinouts be

Pagina 19 - ESD Protection

Encore — Installation and Service Manual 115Jupiter Control of Encore NP Protocol Serial Interface Jupiter Control of Encore NP Protocol Serial Inte

Pagina 20 - Sources of ESD and Risks

116 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide Encore Control of Horizon Serial Interface (RS-422/485)Encore

Pagina 21

Encore — Installation and Service Manual 117Encore Control of Horizon Serial Interface (RS-422/485) Horizon Serial RS-422/485 Cable Pin AssignmentsT

Pagina 22

118 Encore — Installation and Service ManualAppendix B — Encore System Interface Guide Encore to Horizon Protects and UnprotectsEncore control of Ho

Pagina 23 - Encore System Overview

Encore — Installation and Service Manual 119 IndexNumerics10/100BaseT switch 406100884xxFrame 546101000xxFrame 547500 control by Encore 24AAcapp

Pagina 24 - 8053_09r0

12 Encore — Installation and Service ManualSafety Summary Symbols on the ProductThe following symbols may appear on the product:WarningsThe followin

Pagina 25 - 8053_37_r0

120 Encore — Installation and Service ManualIndex date sourcepriority 82Daylight Savings Time checkbox 82Destinationdefinition 28general descript

Pagina 26 - 8053_08r0

Encore — Installation and Service Manual 121Index JJoystick Override 49configuration 50pinouts Encore 51pinouts GSC 52pinouts Kalypso 51jumperC

Pagina 27 - Configuration PC

122 Encore — Installation and Service ManualIndex LEDs 88presetdefinition 29Protectdefinition 29Horizon 118RReboot box 78Reboot button 82redun

Pagina 28 - Sharer PC

Encore — Installation and Service Manual 123Index general description 24insert module 73insert power module 74installation 33LEDs 85mezzanine

Pagina 29

124 Encore — Installation and Service ManualIndex

Pagina 30 - 8053_15_r0

Encore — Installation and Service Manual 13Safety Summary Use proper power cord — Use only the power cord supplied or specified for this product.Gro

Pagina 31 - 8053_07_r0

14 Encore — Installation and Service ManualSafety Summary Ensure mains disconnect — If mains switch is not provided, the power cord(s) of this equip

Pagina 32 - Tie-Line

Encore — Installation and Service Manual 15 Regulatory NoticesCertifications and CompliancesFCC Emission ControlThis equipment has been tested and f

Pagina 33 - Installation

16 Encore — Installation and Service ManualRegulatory Notices Canadian Certified Power CordsCanadian approval includes the products and power cords

Pagina 34 - AC Connections

Encore — Installation and Service Manual 17Regulatory Notices For IEC compliance: The radiant power is detected trough a 7 mm aperture at a distance

Pagina 35 - 8103_00_18_r0

18 Encore — Installation and Service ManualRegulatory Notices

Pagina 36 - 8053_38r0

Encore — Installation and Service Manual 19 ESD ProtectionElectronics today are more susceptible to electrostatic discharge (ESD) damage than older

Pagina 37 - SIO ISA Mezzanine Settings

Affiliate with the N.V. KEMA in The Netherlands CERTIFICATECertificate Number: 510040.001 The Quality System of: Thomson Inc, and its worLdwide Grass

Pagina 38 - ON GDH04

20 Encore — Installation and Service ManualESD Protection Sources of ESD and RisksThe following information identifies possible sources of electrost

Pagina 39 - System Cabling Example

Encore — Installation and Service Manual 21ESD Protection Grounding Requirements for Personnel The information in this section is provided to assist

Pagina 40 - Concertos

22 Encore — Installation and Service ManualESD Protection

Pagina 41 - Reference Cabling

Encore — Installation and Service Manual 23 Section 1Encore System OverviewNote This same Overview section is included in several Encore manuals. If

Pagina 42 - Control Panels

24 Encore — Installation and Service ManualSection 1 — Encore System Overview The Encore system modular design lets broadcasters and other high-qual

Pagina 43 - Control Panel Grounding

Encore — Installation and Service Manual 25Introduction The System Controller Frame has two slots for SCBs and two slots for Power Supply modules, l

Pagina 44 - Ethernet Panel Cabling

26 Encore — Installation and Service ManualSection 1 — Encore System Overview Control PanelsA wide variety of hardware control panels are available

Pagina 45 - GSC Panel Cabling

Encore — Installation and Service Manual 27Introduction Encore System Control FundamentalsDistributed Control SystemThe Encore system uses a distrib

Pagina 46 - to be terminated)

28 Encore — Installation and Service ManualSection 1 — Encore System Overview Sharer PCThe Sharer PC is the PC on which the Sharer is installed. Typ

Pagina 47 - Existing Encore GSC Updates

Encore — Installation and Service Manual 29Routing Basics Preset - Selecting an item (for example a Source or Destination) in prepara-tion for an ac

Pagina 48

EncoreCONTROL SYSTEMInstallation and Service ManualSoftware Version 1.8.1071810311MARCH 2011

Pagina 49 - Kalypso panels KMD, KSD

30 Encore — Installation and Service ManualSection 1 — Encore System Overview Figure 9. A Single Switching MatrixAny of the 10 inputs (numbered 0 t

Pagina 50 - JSO Configuration

Encore — Installation and Service Manual 31Routing Basics Multi-Level Switching DescriptionAll Level TakeAn all Level Take switches the same input n

Pagina 51 - 0619_04_62_r3

32 Encore — Installation and Service ManualSection 1 — Encore System Overview Tie-Line DescriptionTie-lines can be used to link different matrices,

Pagina 52 - Pin # Signal Pin # Signal

Encore — Installation and Service Manual 33 Section 2InstallationEncore System Controller FrameFrame Rack MountingThe Encore System Controller frame

Pagina 53 - Serial Cabling RS-232

34 Encore — Installation and Service ManualSection 2 — Installation Each side of the Encore Controller frame has two screws with spacers (Figure 14)

Pagina 54 - Serial Cabling RS-422/485

Encore — Installation and Service Manual 35Encore System Controller Frame 48V DC ConnectionsWARNING Do not apply a 48V DC power source until all 48V

Pagina 55 - 8103_04_68

36 Encore — Installation and Service ManualSection 2 — Installation Figure 16. System Controller ComponentsControl Processor Submodule Jumper Setti

Pagina 56 - 8279_00_06

Encore — Installation and Service Manual 37Encore System Controller Frame Figure 17. Control Processor SettingsSerial Interface (SIO) MezzanineThe

Pagina 57 - Ports 1 to 8 RS-422/485

38 Encore — Installation and Service ManualSection 2 — Installation The default for the first four ports is RS-232; to set these ports to RS-422/485

Pagina 58 - Nonredundant Frame 6100884xx

Encore — Installation and Service Manual 39System Cabling Example System Cabling ExampleTable 4 list the connectors on the Encore System Controller

Pagina 59 - 8279_00_09

4 Encore — Installation and Service Manual Contacting Grass ValleyCopyright © Grass Valley USA, LLC. All rights reserved.This product may be covered

Pagina 60 - 8103_04_72

40 Encore — Installation and Service ManualSection 2 — Installation Figure 19. Redundant System Controllers Configured Using VLANsThe two System Co

Pagina 61 - 8103_04_73

Encore — Installation and Service Manual 41Reference Cabling Figure 20 shows the same system configuration using two switches. Figure 20. Redundant

Pagina 62 - Figure 38. Redundant Cabling

42 Encore — Installation and Service ManualSection 2 — Installation the Concerto frame. Video Reference 2 is terminated at the first Concerto frame.

Pagina 63 - Control Frame Pinouts

Encore — Installation and Service Manual 43Control Panels Figure 22. Rack Mount Control Panel InstallationControl Panel GroundingEncore Control pan

Pagina 64 - Section 2 — Installation

44 Encore — Installation and Service ManualSection 2 — Installation Control Panel PowerControl panels are powered differently, depending on model. P

Pagina 65 - 8103_03_71r2

Encore — Installation and Service Manual 45Control Panels Figure 24. Control Panels on Three Layers of SwitchesNote While it is possible to directl

Pagina 66

46 Encore — Installation and Service ManualSection 2 — Installation BNC connectors found on the back of the frame. Two GSC mezzanines can be install

Pagina 67

Encore — Installation and Service Manual 47Control Panels ft. (450 m.). The CP Bus is a 1 MBit data bus and will not allow pigtail exten-sions betwe

Pagina 68 - GPI Pinouts

48 Encore — Installation and Service ManualSection 2 — Installation 5. Next type in the following command, followed by the return key, which will re

Pagina 69

Encore — Installation and Service Manual 49Control Panels To correct this issue from the SMS7000 MCPU console interface:1. FTP the files 'Erase

Pagina 70

Encore — Installation and Service Manual 5 ContentsPreface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 71 - Troubleshooting

50 Encore — Installation and Service ManualSection 2 — Installation a GP output (contact closure) that can be connected to one of the 14 GP inputs a

Pagina 72 - 8103_00_56r0

Encore — Installation and Service Manual 51Control Panels Encore/Kalypso Control Panel JSO PinoutsThe pin-outs of the 15-pin D-connector on Encore c

Pagina 73 - Install Controller Module

52 Encore — Installation and Service ManualSection 2 — Installation SMS7000 GSC Joystick Override ConnectorThe installation of the Joystick Override

Pagina 74 - 8103_00_22

Encore — Installation and Service Manual 53Control Panel Keycap Legends ENC-UCP Serial RS-422 PinoutsThe ENC-UCP control panel has two parallel wire

Pagina 75 - Fan Assemblies

54 Encore — Installation and Service ManualSection 2 — Installation redundant RS-232 connections use ports 1, 2, 3, or 4 on the optional SIO ISA mez

Pagina 76 - 8103_00_21

Encore — Installation and Service Manual 55Serial Cabling RS-422/485 Figure 29. Frame Part NumberLate Model Frame 6101000xx BackplaneEncore Control

Pagina 77 - System Controller Boards

56 Encore — Installation and Service ManualSection 2 — Installation Early Model Frame 6100884xx BackplaneEncore Control frames with part numbers in

Pagina 78 - Application Options

Encore — Installation and Service Manual 57Serial Cabling RS-422/485 Figure 32. COM 2 RS-422/485 Cabling New Encore Frame 6101000xxSee Figure 33 fo

Pagina 79 - System Parameters

58 Encore — Installation and Service ManualSection 2 — Installation Nonredundant Frame 6101000xxThe RJ-45 serial connectors on this frame use pinout

Pagina 80

Encore — Installation and Service Manual 59Serial Cabling RS-422/485 The customer supplied cabling from the ivory RJ-45 connector to the device is n

Pagina 81 - SNTP Configuration

6 Encore — Installation and Service ManualContents Sources and Destinations Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 82 - Logging Time and Date

60 Encore — Installation and Service ManualSection 2 — Installation The customer supplied cabling from the Encore Control frame to the device is not

Pagina 83 - ENCONFIG.ini

Encore — Installation and Service Manual 61Serial Cabling RS-422/485 The customer supplied cabling from the ivory RJ-45 connector to the device is n

Pagina 84

62 Encore — Installation and Service ManualSection 2 — Installation The original Encore Control frame part number 6100884xx is noncon-forming and re

Pagina 85

Encore — Installation and Service Manual 63Control Frame Pinouts Control Frame PinoutsRJ-45 PinoutsThe Encore Control Frame has twelve RJ-45 connect

Pagina 86 - 8103_00_05

64 Encore — Installation and Service ManualSection 2 — Installation Table 10. RJ-45 PinoutsRJ-45EthernetWire Color Pin FunctionOrange White 1 TX+Or

Pagina 87 - Troubles hoo tin g

Encore — Installation and Service Manual 65Control Frame Pinouts RJ-45 to 9-Pin D Adaptor Pinouts (RS-232)Table 11 shows the adaptor pin assignments

Pagina 88 - Power Supply LEDs

66 Encore — Installation and Service ManualSection 2 — Installation RJ-45 to 9-Pin D Adaptor Pinouts (RS-422/486)Table 12 shows the adaptor pin assi

Pagina 89

Encore — Installation and Service Manual 67Control Frame Pinouts Table 13 shows the adaptor pin assignments for a RS-422/485 connection on an Encore

Pagina 90 - Scenario

68 Encore — Installation and Service ManualSection 2 — Installation GPI PinoutsGeneral Purpose Interface (GPI) pinouts are shown below. The GPI IN (

Pagina 91 - Salvo Keycap tab

Encore — Installation and Service Manual 69Control Frame Pinouts Note When an SCB is reset manually (using the board reset button or Encore Con-trol

Pagina 92 - Mapping Encore SCB Drives

Encore — Installation and Service Manual 7Contents RJ-45 Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 93 - 9600 8 None 1 None

70 Encore — Installation and Service ManualSection 2 — Installation

Pagina 94 - Monitored Subsystems

Encore — Installation and Service Manual 71 Section 3Maintenance and TroubleshootingService and Replacement PartsReplacement parts can be ordered. C

Pagina 95 - SNMP Agent Licensing

72 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting System Controller ModulesTo Remove System Controller Modules1

Pagina 96 - Device ID

Encore — Installation and Service Manual 73Maintenance To Insert System Controller Modules1. Align the module in the appropriate frame slot.2. Slide

Pagina 97 - NetCentral Capabilities

74 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Power Supply ModulesRefer to Figure 41 for the following proc

Pagina 98 - Register a New SNMP Manager

Encore — Installation and Service Manual 75Maintenance Fan AssembliesThe fan unit and/or the fan filter on the Encore System Controller module can b

Pagina 99 - 4. Send a SET request for:

76 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting To Replace the Fan FilterBefore starting this procedure, ensu

Pagina 100 - SNMP Trap Messages

Encore — Installation and Service Manual 77System Controller Web Pages System Controller Description Web PageThe System Controller Description web p

Pagina 101 - SNMP Console Commands for SCB

78 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Application Configuration Web PageThe Application Configurati

Pagina 102

Encore — Installation and Service Manual 79System Controller Web Pages System ParametersPermits entry of Asset Tag and Location information, for fac

Pagina 103 - Specifications

8 Encore — Installation and Service ManualContents SNMP Agent Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 104 - Appendix A — Specifications

80 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Date, Time and Frame Count Configuration Web PageThe Date, Ti

Pagina 105 - Encore System Interface Guide

Encore — Installation and Service Manual 81System Controller Web Pages Current TimeThe Current Time line reports the current time and date being use

Pagina 106

82 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting The Daylight Savings Time checkbox advances SNTP time by one

Pagina 107 - Table 24

Encore — Installation and Service Manual 83ENCONFIG.ini ENCONFIG.iniEncore v1.8.0 SCBs employs an ENCORE.ini file to set certain system parameters.

Pagina 108

84 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting ;NPBlock is used to control the Router operations by re-dunda

Pagina 109 - Encore System Settings

Encore — Installation and Service Manual 85Troubles hoo tin g SCB Software WatchdogA Software Watchdog is available on Encore SCBs. This utility pro

Pagina 110 - Jupiter System Settings

86 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Figure 48. System Controller LEDs= Green= Yellow= Red8103_00

Pagina 111 - Serial Interfaces

Encore — Installation and Service Manual 87Troubles hoo tin g The LEDs found on the System Controller module are shown in Table 17.Table 17. System

Pagina 112

88 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Power Supply LEDsEach Power Supply module has a single LED th

Pagina 113 - Cable Connections

Encore — Installation and Service Manual 89Troubles hoo tin g System Controller Flash Memory FormattingEach Encore System Controller board contains

Pagina 114

Encore — Installation and Service Manual 9 PrefaceAbout This ManualThis Encore Installation and Service Manual is designed for facility engineers an

Pagina 115

90 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting 4. Run the mkdosfs executable by typingc:\> mkdosfs -w <

Pagina 116 - RS-422 (XY)

Encore — Installation and Service Manual 91Troubles hoo tin g SymptomsTelnet the SCB running the CPS. The console connected to SCB, shall display th

Pagina 117 - 8103_03_64

92 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting 2. Save the Salvo with the new name containing valid DOS FS2

Pagina 118

Encore — Installation and Service Manual 93Telnet Connection to System Controller Telnet Connection to System ControllerUsing the Hyperterminial (or

Pagina 119 - Numerics

94 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Encore System Controller – SNMP AgentMonitored SubsystemsThe

Pagina 120

Encore — Installation and Service Manual 95SNMP Monitoring TrapsIn addition to reporting the status of subsystems, the Encore System Con-troller SNM

Pagina 121

96 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting Figure 50. System Controller Description Window2. Locate the

Pagina 122

Encore — Installation and Service Manual 97SNMP Monitoring 5. Click on Enter License Key button.Figure 52. Enter License Key Window6. Enter License

Pagina 123

98 Encore — Installation and Service ManualSection 3 — Maintenance and Troubleshooting The Thomson Grass Valley NetCentral SNMP Manager automaticall

Pagina 124

Encore — Installation and Service Manual 99SNMP Monitoring 2. Create a new Row in the Trap target table by sending a SET request for:gvgTtCfgEntrySt

Commenti su questo manuale